Any tips? This time around I purchased the t-3 cell model since my pool is below 15k gallons. "As for cleaning the pool filters, I do this every couple of days and doesn't help pressure.". Hello, my salt generator seems to be always be producing at 100% no matter what my output dial is set at. Thanks A. Ray Davis IF that all looks good, consider replacing the capacitor. If that does not fix the issue, the problem goes deeper, and it may be a fatal error in the motor. Hi Davy! it continues to cycle this way. The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). For Pools up to 40,000 gallons. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. On your filter (X-Stream and Voyager) there are two large wing nuts under the lid which secure the pressure gauge and air bleeder. Most impellers spin in a clockwise direction while pumping, but the shaft will spin in both directions no problem. Hi Damon, I would suspect the chattering sound to be a loose stationary switch and/or centrifugal switch on the motor, in the rear of the motor, remove the cover and look for something amiss. I have it on a 15 amp breaker with a few other items, the motor after running is very hot to the touch. *new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. IE9 and older versions are not supported. When pump start it work fine but after few hours water stop moving. 3. clogged pump impeller or very dirty filter. I checked impeller and seems to be spInning freely with no debris. if one of the clips or orings is missing, that is another cause of passing DE into the pool. Gas pressure is ok. Any ideas? Step 4: Verify your pumps pressure. Using natural gas as a heating source. Flip circuit breaker all the way Off, then back on again. Also check the pump basket, and possibly the pump impeller may be clogged, but Id first clean the filter. When the pump comes on a massive amount of bubbles comes out of the return line in the bottom of the pool. When corrected, control will run blower for 5 s then automatically restart after 2 minutes. it will not pull up off the pump basket. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. Power on LED is intermittently on or off. I am getting air bubbles coming from my return jets in my pool. Move switch to center position and adjust dial to a percentage that you think it needs. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. 908-355-7995. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! Capacitor or needs new motor?? Please contact me at mbrad39972@hotmail.com. low speed works fine, pump is three years old. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. In most cases, it means that your motor is on the way out. So we cannot manually rotate the shaft a full revolution. My issue is that the normal operating pressure is around 13-15 psi. . Hi, we had very heavy rain the other night and Im quite sure the rain at least briefly submerged the Hayward 2300 Variable speed pump I have. I Filters, Learn About Hi Ray, the GFI breaker you replaced, is that the pump breaker? The Intermatic T106M timeclock is the standard outdoor timeclock, then you can set it to run 12 hrs daily +/-, or as needed. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. The leak and the surging you are experiencing, could be a result of the high filter pressure. Hi Doug, my first guess would be that the motor was set to accept 230V but was given 115V, or vice versa. Then recharge with a good dose of DE powder. 3 possible solutions. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Any idea what could be the culprit? That is the black cylinder located in the rear of the motor, at 9 oclock. The pump said it came prewired for 230V, but we are running 115V. I have a humming noise when plugged in, but can seem to get the cover off. From the EcoStar technical guide: Check impeller and motor shaft for freedom of movement. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Finally, if the new superpump is larger than the old one, the amperage draw may be too much for the breaker. Replaced battery on top of pump cover and still nothing??? When I then switch the pump breaker off and then back on again it springs into life (every time). 5 Changed the seal It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. When I checked it again, the shaft (impellers) spin freely when tested by hand, but its not actually spinning when powered up? My client thinks the motor was 1hp, but he really not sure. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Remove the cover plate, and use an insulated screwdriver to discharge the capacitor. Be sure that bare wires are not touching other bare wires or terminals, or other metals. PUMP IS 15 YEARS OLD. If you are running the pump at full steam, and then shut it off, while looking very closely at these areas, you may see a quick spurt of water, which is where the air leak is originating from. Hi Frank, two possible reasons might be nighttime moisture (dew), or small insects, both contacting the circuit, on the timer or connected electrical outlet, and causing a brief short, which can trip the breaker. Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. I just bought this pump 3-4 yrs ago? If its bulged, cracked or otherwise looks damaged, you can assume that it has failed. Press and hold the diagnostic button for 3 to 5 seconds. Hi Patrick, so you have power from the breaker to the timer and to the switch. Do I need to use lube on the gasket, how much sand should be in the filter? Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. Hi Jennifer, many Matrix pumps have an on/off switch on the rear bottom of the motor cap end. Not normal, but cant see a reason why that would cause the seal to fail. GFCIs are sensitive, but for a reason. Did you rewire the time clock too, or just the pump motor? Every time I vacuum my pool and then back wash and rinse. The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. Click OK to extend your time for an additional 0 minutes. Thanks for the reply! Is this a new or older installation? i just installed a vspnp hayward pump and when i flip the breaker on it only makes a clicking noise. I have tried a segmented hose and a one piece hose and when it starts to clean, it will clean for about 30 seconds and then there seems to be no water flowing into the pump. For pools up to 40,000 gallons. Our pump wont start at all after opening the pool. Used Cozzia Massage Chair, The low speed works fine. Unlike the error codes that show up on the digital screen, these problems dont show up as an error notification. Pressing on/off buttom followed only by click sound of switch. This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. When I try to turn on high speed it sounds like its jamming and then the breaker trips. If thats not the problem, try soaking the fingers again, with a stronger solution, and/or leaving them soaking longer. I have an above ground 18,000gal poola Hayward SP1580X15 Power-Flo LX 1 1/2 HP pump purchased May 2017. The pump is only one year old. Hi Dave, check that the centrifugal switch is screwed on tightly to the end of the motor shaft. I opened my pool this weekend and started the pump and let it run for few hours before stopping it. I would try a couple of turns of Teflon tape on the threads to create a better seal. Breville Tamper Coffee Kit 54mm, I have water coming out the side of the sand filter where u would back wash? Just opening pool. Bearings produce a loud squealy sound. If its not the cord, I would suggest the filter, cleaning the fingers with a good soak to de-scale and de-grease. We would like to show you a description here but the site wont allow us. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. },
The pump was working well since opening the pool in May, but the last few days it was quite weak. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. I dont want to over tighten it. Hi Cortney, you can buy the cord separately, Hayward pump cord the cause is likely from something arcing within the plug outlet. Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. You should get it back same day or next day, in most cases. Hi check that the pump is not drawing air in, most common areas are around the pump lid, drain plugs and most common, the threaded pipe coming into the pump, which should be sealed with thread sealant like Teflon Tape and/or RTV silicone. The pump is currently configured for 115v. '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. if this is installed below pool water level, also close the isolation valves, to keep the water in the pool, and avoid soaking your socks! Originally it appears that the arrows are just off a little, but not the case. Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? Hi Robin, an F5 code? Fox example, a 1 hp Whisperflo creates twice as much flow as a 1 hp Superpump. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. I would also check all the wire connections (power off) to be sure they are tight, on the breaker and on the time clock, and also inspect for insect infestation, or lizards, mice, etc. The pump has been running for 2 days. Better call an electrician for that though, 2 speed Hayward pool pump motor is very loud only when on high speed. If you lose suction, and the pressure gauge is normal, or lower than normal, that would indicate an air leak in the hose or pipe, or pump, or a clogged pump basket. One washer on each side of the spring, you are correct. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. None of the indicating lights are on. When we turned it on heard a pop and blew fuse. You can also check that the phone cord wire is plugged into the interface, on underside. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. There is water under the motor not sure from where. I have a new Power-Flo Matrix pump. But the process seems to take way too long. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. (GFI 240V 20amp) I just had a pool built for me. If it does not, keep reading. Went to start the pump to prep the pool for the kids and sill attempt to turn on but then stops. Hi Jacob, I would check the connections of the wires first. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
If I wait for a few minutes after that, the pump starts up again at full speed. I have a new above ground pool with a Hayword pump. Thanks. Motors have a thermal overload switch to shut off the motor when it gets too hot. If I leave it plugged in then it stays hot, but if I unplug it then it cools off and itll work till it overheats again. You have both filter pump and polaris pump on one timer? Have had it for 4-5 years and have had no issues. Step 1: Check your system to confirm that you have programmed the correct cell size. Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. We cannot get it going again. how to watch past broadcasts on twitch. Looking for pool parts? I immediately unplugged it and the plug was black and the extension Outlet was melted. It makes humming sound 1-2 times before starting. They function as the starting battery for the motor, to help it get up to speed quickly. Any thoughts? Inspect the motor for any burns evident on the casing as many times, an overheating motor will be shorted across the windings, and will soon fail. You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. Third guess would be that the connections were not tight on the new motor. I have this same Drive Error Message. Reset the average salt level on startup and whenever you replace your cell. Hi Davy. Anyone have this issue or have any recommendations? If your pump is made of plastic, it must be the bearings, failing so hard that it is causing the motor to overheat. My client just had his pool guy open his pool for the summer yesterday and they discovered voltage in the pool. Thank you! You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. If thats not the air leak, check the pump lid o-ring, Superpump square lid rings sometimes get twisted easily. Lube Gasket (after cleaning, with a rag lube with Teflon or Silicone based pool lube) and 3. View Details Usfitnessfinder.com. The problem lies where the power dies [note to readers: motor cycling is not the same as pump cycling, where the water flow starts and stops, here I am talking about the motor itself starting/stopping], I have a Hayward sp2607x10 pump. I have a max-flo XL pump how high should it read it keeps going over 20 psi is this normal. Davy, after going back into the pump again, i have come to the conclusion that the bearings are going out in the motor. dr myers ultrasound. If they are tight, pull out the cartridge and drain the tank whatever it is may be laying in the bottom of the tank. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? You find these in our valve parts department or use one of our multiport valve rebuild kits. There is an o-ring on the union, and also on the valve stem, and they can start leaking over time. spun and is loosely spinning. What do I need to do to fix this? Now if it really is your pump, and not the heater making this noise, that I cant explain, must be the heater? If your pool pump is not pumping water, check that all suction and return valves are open, and the pump lid is on tight, with the lid o-ring in place. Its less than 2 wks old.
(or 110V, if wired 120V). Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). However, no matter what. I hadnt run my pumps in a couple of weeks. If your new pump is the exact same make/model/horsepower as the old pump, then the pump is not the problem but if you switched make/models check the pump flow curve, because even though it may be the same hp, different make/model pool pumps produce Vastly different flow rates. You dont need a seal plate kit you can just use the shaft seal SPX1600Z2. Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). We would like to show you a description here but the site wont allow us. Hi Joe, I would first suspect an air leak, Superpumps can also draw air from a loose drain plug and easily around the square lid gasket but the usual suspect is the pipe coming into the pump. Check the switches in the back of the motor, the centrifugal on the end of the shaft, and the stationary, mounted at 6 oclock, to look for any loose screws or insects, or mis-alignment. presto, all working good! likely not a fan or impeller problem, because at 3500 RPM (or less), it would wear down anything broken in just a few minutes. Salt chlorine generators are great products. I think the problem is a nick in the face of the salt cell that the unions o-ring seals against, but I cant feel anything there so its not like a giant burr or anything. Yours may have become weak, or damaged somehow. After just a few minutes the flow slows down to almost nothing. You will need a new plug and a new outlet and maybe a new pump too (? You should also check for loose, crimped or broken wires or rusty terminals on the capacitor. Hi Shannon, right now it is a defective capacitor, not sure about the rest of the motor, but is probably OK. You can use a bent paperclip to ream out the orifices. I have an older Hayward Pool pump for an above ground pool. Hey John The pump is working great but concerned about the hot cord. Check that hoses are clamped tight to fitting. The new pump then starts to overheat and it shuts off. I shut the pump down the other night and it will not run. 7. inspect breaker, turn off breaker to pool from house main panel). I just replaced the flow switch and that solved one problem, but now Im only able to produce chlorine when the system is on Super Chlorinate. Just bought a hayward super II pump. Theres not much room back there for wires, and if they get too close to other things. Turn on heater and see if you can narrow down the noise. The print and bearings were replaced. I purchased a hayward powerflo matrix 1.5 pump and Proseries 21 Filter a week and a half ago. Everything coming in appears to be tight. bought a SP2610x152s super pool pump 1.5 hp. Hello, I have a H200 natural gas heater . When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. Could vibration over time wear the pump housing? But just like any sort of equipment, even the most well-made products sometimes need repairs. 5. low water level or skimmer weir blocking water flow The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Is it problem of filter ? If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Thanks in advance! Also check all the wires, from the back of the terminal board, to the stat. Usually its 4 bolts or its a clamp band that connects the seal plate to the volute or strainer housing. The control panel says that theres a driver error. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The original pump (assy A) smells burnt. A lb of DE is by volume, equal to a 1 lb coffee can, or about 4 cups of dry measure. The filter is clean. Any new postings here are unlikely to be seen or responded to by other members. Hayward Blue Essence Troubleshooting, Replace the seal in the same orientation as you removed it, and reassemble. I was attempting to replace shaft seals when something went wrong. We have just replaced the seal assembly as suggested by a Hayward rep already. If I let it sit I can turn it on again, but just for about 20 seconds. i have an in ground pool. Humming Motor: If the pump motor makes a humming sound when starting up, you likely have a clogged impeller. Hi Davy, I connected Line 1&2 plus bond. What is the incoming voltage on a H-150 pool/spa heater ? This past week the motor sometimes starts sometimes does not sometimes starts and turns itself off. The article says: Thanks! Thanks for your time! IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. Or maybe the glue that Im assuming is no longer working? Its a Hayward pump. They have to stick out about 1/8 wider than the plunger disk. It seems to be coming from the wet side of the pump the strainer housing. Then check the GFCI for loose wires. , I have a 1 hp Hayward 2 speed motor. The higher the pump is elevated above the water level, the more struggles this can cause. But lack of sand should not cause a leaking problem. It had been running ok this summer. Is the replaced pump and motor problem? The capacitor is at 9 oclock and the thermal regulator at 12 oclock. Its running now but when I turn it off it wont restart. search, pool & drain cover safety Both the pump motor and Polaris are wired out of the timer and the timer seems to be working correctly and I checked it by checking the voltage at the motor with the switch in the off position and then again with the switch in the on position. Compare to Hayward T-Cell-15 Would this make the breaker flip? Outlet works fine. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). IF its a broken off grease cap, tap in a sharp screwdriver into where it threads in, to get some bite, and then slowly and firmly back out the broken off threaded connector, turning CCW, then replace with a new Grease Cap, or a 1/8 threaded plug. 2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). Sometimes you can pull out the clog with needle nose pliers. the termistor was blown. You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. You can use a pool putty to seal up some incoming leaks, but sometimes new parts are needed. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. You can assist by removing the back cover and placing a fan behind the motor and try again after a day. If not, keep reading. Hi Larry, valid question. If you have other questions, you can email me Davy, at swimmers@intheswim.com. Could the water have damaged the motor ? I have a D.E. Inspect and clean your cell. I filled the pool to the level line, but the air bubbles stayed. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | We would like to show you a description here but the site wont allow us. I took off the cover to see the circuit board and all looks ok but then it started coming on and off randomly while I was standing there. This is a salt pool not sure if that matters in the question. I have a six year old Hayward sp3400vsp and theyre recommending I replace it with the pen take intelliflo. Hi, could be that the capacitor has worn out. Gas fired pool heaters are similar to a home gas-fired furnace, with the main difference being that a pool heater heats water and a home furnace heats air. Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping Im still getting air? Im thinking the new pump might be set for 230 and wiring is for 115. Christin, many aboveground pumps plug into a GFCI outlet, check that the TEST button is not popped out. Thanks. Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. Power can be checked at the motor terminals, with a multimeter set to AC volts. Also, using Teflon pool lube on the pump lid oring should help. If pressure is lower than normal check for air leak on the suction side of the pump, or a clogged impeller, or low water level, stuck skimmer weir, or closed suction valves. Pool pump already went out a few months ago. Second thing is to see if the Motor Shaft Spins Freely, rust can develop which can bind up a motor. The usual spot is the pipe that threads into the pump did you use Teflon tape and/or silicone sealant on the threads? Pump shutoff during 24 hours of pouring rain. Also look for loose wires or corrosion (stored next to chlorine tabs during winter?) Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions.