Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. The other gears move very slowly, and appear to not move at all, except for one I believe? i have an oval pool that is closed for the winter but there ha been a problem. Theres power to the pump using the manual override. My timer clock does not run and the manual on off switch does not turn off the pump motor. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. Does it need lubricant or something? How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! "author": {
Also be sure that the front dial is engaged with the gear located behind the dial. This morning the customer said it wasn't turning off. What Im wanting to do is just disable the turn off/on and just keep power 24/7. Wont work manually or by timer function. You can replace it but its really just easier to replace the entire mechanism. Save my name, email, and website in this browser for the next time I comment. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. Timer must be reset for current time after power outage. The most common pool timer used for inground pool pumps is the Intermatic time clock. It was always fine before. As an Amazon Associate we earn from qualifying purchases. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. Hi, I got the same problem as my clock not working. Any suggestions on how to troubleshoot? Does the manual lever stay in the on position always? HI Ben, yes just remove the OFF tripper, and the clock will always be ON. Tighten down all brass screws securely, to hold all wires firmly in place. "width": "611",
How do you know if your pool timer is bad? #1. If you dont think the mechanism is the issue, move onto the next step. Is it possible to do this by loosening the timer screw a bit? Thanks in advanced. The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. Ordered new ones. Video of the Day Trippers We may earn a small commission. Same goes for slipping timer dogs! Read full answer 2/14/2023 3:20:07 AM To do this, pull the yellow-faced time dial (clockface) toward you. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
1-48 of 242 results for "pool timer trippers" RESULTS. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Gently tighten the screws to securely hold the dogs in place. Hi Matthew T104 can only turn one pump on and off. screwfindinganame on June 18, 2013 at 11:36 pm I would suggest calling Intermatic and suggesting that idea and a free replacement? Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. Flip it from where it is now, to the opposite side. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. There should be an off pin and an on pin. You off course will want to adjust one time pin at a time. Things are working fine and all of a sudden the pool pump did not start in the morning. I need to replace a timer for my pool vacuum. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. This is hard to check if you are not qualified. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. "image": {
Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. "width": "611",
Give it a little squirt of WD-40 or similar lubricant. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. not sure what is the problem. When I put the new one on, the trippers do not work. the problem lies, where the power dies as they say. I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. I have the PF1202T timer on my pool. I have a sweeper set on auto on the second timer and it is working correctly. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! You can turn off Freeze protection and it should stop, or replace the probe if faulty. I not sure if this is the best timer to use. Hi, then the power for the clock must be from the switch, and not from the breaker? do i need to do something different? The same happens prior to the timer reaching the off tripper. }
. Power surges could be to blame. The terminals on the wires aren't tight. You may need to adjust the meshing of the timer motor gear so it runs the clock. It stays on until I turn off the circuit breaker. Now it worksbut its really fast. Any ideas? I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. Thanks for any help you can give. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. Thanks! Thank you for choosing Intermatic! The capacitor for the motor may be bad. It is a mechanical issue between the trippers and the switch lever. We are on our third timer. P.S. Turn the power off at the breaker box and carefully remove the wires to the clock. It would not reset itself and could not get power back to the timer. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. "address": "",
There is a second switch between the breaker and the timer. I flicked the switch between on and off and it will not shut off. Hi Bob, you have two blacks and one neutral? My pool pump and skimmer are on two different motors. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? Close. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. Timer not tripping pump on. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Hi there, Related Reading: Should You Get a Pool Pump Timer? Back when I was a young technician I was taught to always look for the easy things and use all my senses. This pool timer is waterproof, heavy-duty, and accurate. That was probably what burned the plug. Or there could be a bad relay in the control panel, if you have ice cube style relays. Do not remove the screws from the trippers. My pump has a plug. With this model can I control both of these motors with two different on and off times. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. Go for it, a little maintenance expense. Hi Davy, I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Does the tripper work on other areas of the clock, like near the off tripper? The problem lies where the power dies, youve probably heard that before. Ideally, the switch would be placed after the timeclock, not before. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. I currently manually turn it on and off. Electrical Monke Aug 25, 2021 #22 It's broken. "wordCount": "1259",
Move the start and stop pins to appropriate times for swimming pool filter operation. Tighten them with a wrench. the timer was directly plugged into a gfci and the pump directly into the timer. The gears in mechanical timers can get damaged. The problem is the 'off' tripper. Followed all directions and even watched YouTube troubleshooting videos. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. I have an Intermatic t104. I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Theres an issue with the wiring between the circuit breaker and the timer. Any suggestions as to how to test clock feed? Take a good look at the position of the pins and write down the locations. Can breaker be bad? Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. If the pump doesnt come on, follow the steps below. View more property details, sales history and Zestimate data on Zillow. Ft. 750 Joshua Dr, Hollister, CA 95023. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. 2. To set it, you just move the on/off "trippers" where you want them. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. How can it keep time if lever is in off position (manual lever). It only takes a small amount of dirt to foul up gears so look carefully. If it doesnt, there could be an issue with the clock face or gears. Any thoughts before I run out to replace it? I tried to change the on tripper due to Daylight savings time & dropped the screw. But if the timer doesnt come back on after a storm, there could be an issue. #9. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. You will first want to look at the pool timer and see if you have two timer pins. Proceed to step 4 to check the timer itself. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Hi Carlos, is there a GFCI outlet in the circuit? If power is coming to the timer motor, you will clearly see the gears moving through the small window. 220V clocks have 5 terminals, 110V clocks have 3 terminals. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. . If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. I took the electrical box cover off and check the breaker connections. No broken or loose wires visible. Just some ideas. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). Confused. Are the gears engaged, in the center, behind the dial? "
Pool Timer Not Turning ON or OFF!! Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . how do I check the manual over ride switch to see if it is off? No luck. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Once you have confirmed that you timer is working you will need to adjust the timer pins to reflect the time you want your filter system to turn on and off. Your timer is on a 24-hour cycle. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. Paul, it could be that you got a 50hz motor, instead of a 60hz? So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. Or other advice or explanation. This will disengage the dial from the . Thank you so much. Now The ice and snow have melted and the cover is getting in deeper. Is it Necessary? My clock seems to work but but the on and off switch does not turn on the pool pump. Hi, Davy, seeing lots of complaints here. Sometimes during power surges or lightning, these will be fused together and not come apart. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. Check that the TEST button has not popped out. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. Hi Davy, It may or may not reduce the noise level however. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. I unscrewed the clip and put it back on and its still doing the same thing. Put them back on and tighten them. Clock not turning or making any sound. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. Hi, new timer out of the box, 200V. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. My intermatic pool timer will not automatically turn on. any suggestions about how i might avoid another situation like the above would be appreciated. Turn in either direction and align the exact time-of-day on . If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. My Polaris booster pump ONLY turns on via the trippers. Is it keeping time normally? Does this give you a better idea of the problem? Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. Thanks again for your help. I have Model T40004RTe. More. "primaryImageOfPage": {
Line is incoming, Load goes to the pump. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). Hi Bev, seems legit to me! Reasons Why Pool Timers Stop Working 1. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) You should always be able to switch your pump on and off manually at the timer. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. I bought a new timer and replace the T104 timer clock. Or may be bent and not come together. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. "@context": "https://schema.org/",
It is still moving and it will trip off but not on. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. My timer doesnt seem to be working or my pump in either speed. Just turn the timer wheel until the correct time of the day is aligned with the timer marker that is mounted in front of the wheel. what causes timer on/off pins to bend and how can i prevent timer pins from bending. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. I dont see any debris blocking the off dog. View community ranking In the Top 5% of largest communities on Reddit. If you have gone back after a few hours and the pins have moved that means you have electrical power to your timer and it is working. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . If your pool pump timer is beyond repair, call a professional to replace it. It is not warped in any way. Ask Your Own Pool and Spa Question Thanks in advance! Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. Make sure the middle time pointer is tight. we purchased the house 5 years ago so not sure how old the timer is? It randomly loses the time that it is set to. If I manually push the lever, it moves without much pressure. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Black goes to _1 Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. Repeat the process for the "on" pin. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. This product is certified by Amazon to work with Alexa. You most likely just need to now set the pins and the clock and your timer will work. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. Any idea what may be causing this? The pump worked perfectly before I unscrewed it. However, after several hours, maybe overnight, the associated breaker will trip. },
A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. GFCI breakers trip at a very low threshold, doesnt take much. Hello have a question some what related. Or might find something else. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. If you dont have the voltage here you have an issue with either the wiring or the breaker. Any suggestions? 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Sometimes the trippers get loose or damaged. 3 Baths. "datePublished": "1/10/2020",
Everythings OK now, unit works just fine. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Sometimes old power wires split or short-out. That way I could schedule the pump once again. Push down on the timers until they snap into place. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. Basically 12 real life hours equals about 14 on the timer. Any other thoughts? For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. I replaced the pump and still nothing is moving. Inside, the 1 gear on the right side can be removed to access a metal bar. If any of these issues occur your timer will not work properly. If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. When the trippers are done up, you shouldnt be able to move them with your hands. Found the answer. Im wanting to use T101 to wire my above ground pool pump. There are many reasons why your pool timer may not be working. If the pump comes on, you definitely have power to the timer. http://waterheatertimer.org/Tork-timers-and-manuals.html the ground wire? There is power; gears are moving. Did you find the issue? It should loosen up after a few goes when the grease and gunt dissolve. However, the timer will stop around 10pm everyday and will not continue moving forward again. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. Breakers go bad sometimes, after many years. Pop-in a new timer mechanism, and replace the wires to the previous configuration. A timer replacement would be required. Yes, seen that before! This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Are the trippers slid all the way onto the dial fully? Is the timer repairable, or should I just install a new one? My original timer worked for 5 years then the clock stopped and I heard no sound. However the new breaker is in a constantly tripped position. How can I fix this? In most cases like this, replacing the trippers is the solution. Today is the second day that I have had to turn it on manually. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. It sounds like the Line and Load wires are reversed. I noticed that they had stopped. They should be straight, if not, replace them. Hi, hope you are doing well. Assuming the wiring is all correct. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to.

Military Spouse Working Remotely In Germany, What Is Vigoro Brown Mulch Made Of, Articles P